REGION: EMEA
ISSUE: DriveStation Duo LED / Audible codes
CAUSE: LED colors and audibles indicate maintenance or troubleshooting need
PLATFORM: DriveStation Duo
SOLUTION:
| LED |
Color and Action |
Meaning and Troubleshooting |
| Disk1 or Disk2 |
Green, Flickering |
The Disk is being accessed. |
| Disk1 or Disk2 |
Red, Stable |
The Disk1 or Disk2 failed. Replace the drive. |
| Disk1 or Disk2 |
Red, Flashing |
Rebuilding RAID array is performed. Don't turn the unit off. Otherwise, restored data is lost. (Red and green flashing continues frequently because of disk access.) Estimated rebuilding time is 7 to 8 hours for 500GB model, 11 to 12 hours for 800GB. 1.0TB and 1.5TB model are more. |
| Disk1 and Disk2 |
Red, Stable on both |
Replaced disk capacity is lower than original one. Unable to start rebuilding RAID. |
| Beep Status: |
| Beep Code |
Meaning |
| Alternating continuous short beep then silence |
Internal cooling fan is stopped. |
| Continuous beep |
Hard disk unit temperature is too high. |
| Three second beep then silence |
The Disk1 or Disk2 is failed. Replace the drive. | |